Thank you for Subscribing to Med Tech Business Review Weekly Brief

Early Cross-Functional Collaboration Strengthens Medical Device Development


Bringing Manufacturing and Quality Into Development
Throughout my career, I have seen the costly rework that occurs when manufacturing and quality teams enter projects too late. Involving these teams early helps translate design intent into products that can be manufactured reliably and efficiently. Previously, product development (PD) teams would spend time with surgeons and marketing representatives at expositions before returning to spend months designing new systems to address surgeons' needs. Once designs were completed, PD would pass them to manufacturing engineering, often just before the November and December holidays. Manufacturing teams would then scramble to prepare prototype sets for the upcoming AAOS Academy in February and March. During this period, manufacturing teams would establish and optimize processes before executing first article inspections. Quality teams would develop production measurement methods, conduct GR&R studies and generate measurement instruction sheets. PD would then return from the Academy with design adjustments, sometimes substantial ones, and the entire cycle would begin again. Improved technology has made early collaboration more common. Manufacturing and quality engineers began receiving CAD models earlier in the development cycle, reducing the last-minute scramble to establish raw materials and measurement methods. Teams could build processes around preliminary CAD models, then update and regenerate them as revised models became available. This approach often saved weeks during the ramp-up to launch and thousands of dollars in hard gages that could become obsolete after a simple datum or dimensional change. Early collaboration has helped medical device OEMs reduce time to market, rework hours and spending on gages that never reached production. A Datum Decision With Measurable Impact One example of what can happen when early collaboration is overlooked involved a trauma femoral drill guide instrument set. The instrument was developed to help surgeons target femoral nail fixation drilling. The design called for carbon fiber composites to support radiolucent fluoroscopic imaging. A precision stainless steel thimble was epoxied into the instrument's base to engage the implant. At the opposite end, a large flat surface held two precision, perpendicular pins used to target the nail's cross holes during surgical imaging. When establishing the GD&T layout, PD located the datums on the thimble's small keys, measuring approximately 2 mm × 3 mm × 5 mm. Achieving the tight positional tolerance required for the pins at the opposite end was already challenging, particularly given the potential movement of carbon fiber during autoclaving. Years ago, my GD&T professor described positional tolerances in three-dimensional space as “defining the virtual condition.” Mathematically, datums can be located at either end of a component. Common PD practice, however, is to use the features that locate the implant. In this case, those features were the small keys. When the coordinate measuring machine (CMM) technician established the datums from these features, even the slightest deviation from perfection caused the pins at the opposite end to fall outside their tightly controlled positional tolerances. The result was an artificially high scrap rate on an expensive instrument. Working with PD and quality engineering, we reversed the datum structure. The 16 mm × 24 mm planar feature established the primary orientation, while the precision pins established the secondary and tertiary datums. We then remeasured the positional location of the keys. Scrap was immediately reduced by 30% across 100 sets.Early collaboration has helped medical device OEMs reduce time to market, rework hours and spending on gages that never reached production.”